Weak showers and banging pipes usually come down to a short list of causes, and most of them can be narrowed down with an inexpensive hose gauge and a few minutes of testing. This page walks through how we diagnose pressure problems in Lee, Collier and Charlotte County homes, what the plumbing code says, and when the problem belongs to your utility instead of you. If you’d rather have us test it, call (239) 518-4198.
Low pressure and high pressure are different problems
People call us about low pressure far more often than high pressure, but high pressure does more damage. Low pressure is an annoyance: a shower that never quite rinses the shampoo out, a second-floor bathroom that dies when the dishwasher runs, an irrigation zone that won’t reach the edge of the lawn. High pressure is quiet until something fails. It shortens the life of supply lines, toilet fill valves, faucet cartridges, ice maker lines and water heaters, and it’s behind a lot of the burst braided connectors we see under sinks.
The two also get confused. A house with a failing pressure reducing valve can swing between both, running at 110 psi overnight and then sagging to almost nothing when two fixtures open at once. So the first job is always to measure, not guess.
Static versus flowing pressure
Static pressure is what the system holds with every fixture closed. Flowing (or residual) pressure is what’s left while water is moving. A healthy system drops a little when you open a tap. A system with a restriction, like a clogged filter or a corroded galvanized line, can show perfectly normal static pressure and then collapse the moment water flows. That’s why we test both.
How to test static pressure at a hose bib
You can do a useful first check yourself. Hardware stores sell pressure gauges that thread onto a standard garden hose connection. Pick the outdoor spigot closest to where the water service enters the house, and make sure it’s on the house side of any PRV, softener or filter if you want to see what the fixtures actually get.
- Turn off every fixture inside and outside, including irrigation if it runs off the potable line, and make sure the ice maker and washer aren’t filling.
- Thread the gauge onto the hose bib by hand and open the spigot all the way.
- Read the static number. Leave it for a few minutes and watch whether it creeps up, which points to thermal expansion or a PRV that isn’t holding.
- Have someone open a bathtub faucet fully and read the gauge again. That’s your rough flowing pressure.
- Repeat the test early in the morning or late at night. Utility pressure often runs higher when neighborhood demand is low.
- If you have a gauge with a red lazy hand (a max reading needle), leave it on overnight. It records the highest pressure the system hit while you slept.
Most homes are comfortable somewhere in the 50 to 70 psi range. A static reading under about 40 psi usually feels weak, especially at upstairs fixtures and showers with modern low-flow heads. Anything above 80 psi needs attention, for reasons covered below. If your hose bib leaks around the stem while you’re doing this, our hose bib repair page covers that.
The 80 psi limit and when a PRV is required
The Florida Building Code, Plumbing follows the International Plumbing Code numbering for water supply. Section 604.8 covers water-pressure reducing valves: where the static water pressure in a building exceeds 80 psi, an approved pressure reducing valve has to be installed to bring the distribution piping down to 80 psi static or less. The valve is installed with a strainer ahead of it so debris doesn’t foul the seat, and it needs to stay accessible for service. Local amendments can add to this, so we check with the building department on permitted work.
The rule applies to what’s in the building, not what’s in the street. Some parts of our service area see high street pressure, especially homes close to a main or a booster station, while others never get near 80. That’s why two houses on the same street can have different setups: one with a PRV right after the meter, one without.
One more detail people miss. Most tank water heaters carry a temperature and pressure relief valve rated to open at 150 psi. A house running at 95 psi static that heats water in a closed system can climb toward that number every time the burner fires, which is why a dripping T&P valve is often a pressure symptom and not a water heater defect. Our water heater page goes deeper on the heater side.
Signs your pressure reducing valve is failing
A PRV is a spring-loaded diaphragm valve. Inside it there’s a seat, a diaphragm and an adjusting screw, and in Southwest Florida’s hard water those parts scale up and wear out. Many residential PRVs give years of service, but they don’t last forever, and when they go they tend to fail in one of two directions.
Failing open (pressure creeps high)
- Static pressure reads well over the valve’s setting, or climbs overnight on a max-reading gauge.
- Toilets run or hiss as the fill valve struggles to shut off.
- The T&P valve on the water heater drips or discharges.
- New faucet cartridges or supply lines fail sooner than they should.
Failing closed or restricted (pressure sags)
- Pressure drops sharply when more than one fixture runs.
- The strainer screen ahead of the valve is packed with sand, scale or pipe debris, often after utility work in the street.
- Pressure surges and then drops, which we hear described as the shower pulsing.
Sometimes the fix is cleaning the strainer and resetting the adjustment. More often on an older valve we replace it, because rebuild kits for some models are hard to find and the body itself can be scaled shut. Replacement usually means shutting the main, cutting in the new valve with unions, and setting it with a gauge. If you can’t find your main valve, our main water shutoff guide shows where they usually hide in local homes.
Thermal expansion and expansion tanks
Water expands when it’s heated. In an open system that extra volume pushes back out to the street main and nobody notices. Once a PRV, a check valve or a backflow preventer goes in at the service, the system becomes closed and that expansion has nowhere to go. Pressure spikes every time the water heater runs a cycle.
The Florida plumbing code addresses this in Section 607.3, which requires a means of controlling increased pressure caused by thermal expansion where a storage water heater is supplied through a device that prevents backflow. In practice that means one of two things: a thermal expansion tank, usually on the cold inlet at the water heater, or an auxiliary relief valve on the water service. For single-family homes with high street pressure, expansion tanks are the more reliable choice because relief valves in that situation tend to drip and fail.
Expansion tanks have their own failure mode. They have an air charge behind a diaphragm, and that charge has to match the home’s static pressure. If the tank was charged at the factory setting and the house runs at 70 psi, it isn’t doing much. If the diaphragm ruptures, the tank fills with water and does nothing at all. A quick check: with the water off and pressure relieved, tap the tank. A tank full of water sounds dull all the way up, and pressing the air valve core lets out water instead of air.
Galvanized pipe and other restrictions inside the walls
Galvanized steel water pipe was common in American houses before copper and plastic took over, and we still find it in older Fort Myers neighborhoods, in early additions, and in short sections where a previous owner patched a line. Galvanized corrodes from the inside. Over decades the zinc coating wears through, the steel rusts, and the bore closes up with scale until a 3/4 inch pipe may pass water like a much smaller one.
The giveaway is a house with normal static pressure at the hose bib and miserable flow at the fixtures, often worse on the hot side, sometimes with brown water after the system sits. Cutting a section and looking at it settles the question. There’s no cleaning that restores galvanized, so the real fix is replacing it, whether that’s a single run or the whole house. Our whole-house repiping page explains how that work goes and what materials we use.
Other restrictions we find: a half-closed gate valve someone forgot about, a crushed or kinked flexible connector, a corroded shutoff stop under one sink, and debris lodged in a tee after the street main was flushed.
Meter, curb valve and service line problems
Between the street and the house are a few parts that can choke flow without anyone noticing. The meter box usually sits near the road in the right-of-way. Inside it there’s the meter and a valve on the utility side, and many homes have a customer-side shutoff as well. Lee County Utilities, for example, maintains the service up to and including the meter and meter housing, and everything beyond the meter is the property owner’s responsibility. Other utilities in the region draw the line in much the same place.
- A curb valve that was partly closed during a meter swap or service call and never fully reopened.
- A customer-side ball valve that’s half closed or has a failed internal ball.
- A buried service line that’s been crushed by a vehicle, root growth or settlement, or is leaking underground.
- An undersized service from the original construction feeding a house that has since added bathrooms, a pool fill and irrigation.
If the meter’s leak indicator is spinning with everything off, the pressure loss may be a leak, not a restriction. That’s a job for leak detection first, and then water line repair if the problem is in the service line. Don’t park over the meter box or let landscaping bury it; utilities need access, and so do we.
Wells, pumps and pressure tanks
Plenty of homes in Lehigh Acres, Alva, Buckingham, Golden Gate Estates and the rural parts of Charlotte County run on private wells. There’s no utility pressure to blame here. The pressure you get is set by the pump’s pressure switch and held by the pressure tank.
Most residential switches run a 30/50 or 40/60 psi range, meaning the pump turns on at the lower number and off at the higher. The tank’s air precharge is normally set about 2 psi below the cut-in point, measured with the pump off and the tank drained. When that charge leaks away or the bladder fails, the tank stops storing water and the pump short-cycles, clicking on and off every few seconds. That burns up pumps and pressure switches.
- Pressure swings hard between strong and weak while a shower runs: suspect the tank precharge or a waterlogged bladder.
- Pressure slowly fades over months: suspect a worn pump, a clogged intake or a dropping water table during the dry season.
- No water at all after a storm: check the breaker and the pressure switch contacts before assuming the pump is gone.
- Sediment or sand in the strainer and aerators: the well screen or pump intake may need attention.
We diagnose and replace pumps, switches and tanks; see well pumps and pressure tanks.
Softeners, filters and whole-house treatment
Water treatment equipment sits right on the main line, so when it clogs, the whole house feels it. This is one of the most common causes of a sudden pressure drop we see, and one of the easiest to rule out.
Most softeners and whole-house filters have a bypass valve on the control head. Put the system in bypass and open a faucet. If pressure comes right back, the problem is in the treatment equipment, not the plumbing. Typical culprits are a sediment cartridge that’s gone brown and solid, softener resin that’s broken down into fine particles and packed the bed, resin beads that escaped through a cracked distributor tube and lodged in faucet aerators, or a carbon tank that’s channeled and fouled. Well systems with iron or sulfur filters see this faster.
Undersized equipment causes a similar complaint. A small cabinet softener with a 3/4 inch valve on a large house with multiple showers can drop pressure noticeably under demand even when it’s clean. Our water softeners and filtration page covers sizing and service.
One fixture or the whole house: a quick diagnostic table
Where the problem shows up tells you most of what you need to know. Use this as a starting point before calling anyone.
| What you notice | Most likely cause | First thing to check |
|---|---|---|
| One faucet weak, everything else fine | Clogged aerator or worn cartridge | Unscrew the aerator and look for scale or resin beads |
| One shower weak | Clogged showerhead, flow restrictor, or a scaled mixing valve | Remove the head and run the valve without it |
| Hot side weak at every fixture, cold fine | Water heater inlet or outlet restriction, scaled dip tube, galvanized nipples | Check the valves and fittings at the heater |
| Whole house weak, sudden onset | Clogged softener or filter, PRV strainer, partly closed valve | Put the treatment equipment in bypass |
| Whole house weak, gradual over years | Galvanized corrosion, failing PRV, undersized service, failing well pump | Hose bib gauge test, static and flowing |
| Pressure high or climbing overnight | PRV failing open, no working expansion tank | Max-reading gauge overnight |
| Pressure pulses or surges on a well | Waterlogged pressure tank or low precharge | Watch the pump cycle and check the tank charge |
| Whole neighborhood low | Utility main break, flushing, or high demand | Check with your utility before calling a plumber |
Single-fixture problems are often a quick repair. Our faucet repair and shower valve repair pages cover those specifically.
Water hammer and arrestors
Water hammer is the bang you hear when a valve shuts quickly and a moving column of water stops all at once. Washing machines, dishwashers and ice maker solenoids are the usual triggers because their valves close in a fraction of a second. Single-handle faucets slammed shut can do it too. High static pressure makes it much worse, so the first step is often checking the PRV, not adding hardware.
The model plumbing codes require water hammer arrestors where quick-closing valves are used, and installed arrestors are expected to meet the ASSE 1010 standard. Older homes often have capped vertical pipe stubs called air chambers instead. Those work at first, but the trapped air dissolves into the water over time and they stop doing anything. A mechanical arrestor with a sealed piston or bellows doesn’t have that problem.
- Bang right after the washer finishes filling: point-of-use arrestors on the washer box hot and cold.
- Knock when a toilet finishes filling: often a worn fill valve, sometimes loose pipe straps in the attic or wall.
- Rattling while water runs, not just when it stops: loose pipe or a vibrating valve, which is a different fix.
- Hammering everywhere: measure static pressure before anything else.
When the problem is on the utility side
If your neighbors are seeing the same thing, or the pressure at the meter itself is low, the issue is likely the utility’s. Main breaks, line flushing, precautionary boil water notices and peak-season demand can all drop pressure for a while. Before you pay for a service call, check with whoever sends your water bill. In our area that’s usually one of these:
- Lee County Utilities: much of unincorporated Lee County, including much of Estero and San Carlos Park.
- City of Cape Coral Utilities: potable water, reuse irrigation water and sewer within the city. Their after-hours emergency line for main breaks is (239) 242-3400, and the utilities department is (239) 574-0700.
- City of Fort Myers Utilities: inside city limits.
- Florida Governmental Utility Authority (FGUA): systems in Lehigh Acres and parts of North Fort Myers.
- Bonita Springs Utilities, Island Water Association on Sanibel and Captiva, and Greater Pine Island Water Association in their areas.
- Collier County Utilities and City of Naples Utilities in Collier, Charlotte County Utilities and the City of Punta Gorda in Charlotte, and Englewood Water District around Englewood.
In Cape Coral, remember that irrigation water comes through a separate system from your drinking water, so weak sprinklers there don’t necessarily mean anything is wrong with the house supply. If the utility confirms pressure is normal at the meter and you’re still weak inside, the problem is on your side, and that’s where we come in. For local water chemistry and how it affects fixtures, see our Cape Coral water quality guide.
HomeFlow works throughout Lee, Charlotte and Collier Counties, Monday to Friday, 8am to 5pm, and we take urgent calls by phone after hours when we can. Call (239) 518-4198 or use the request form.
Common Questions
What water pressure should my house have?
Most homes do well somewhere between 50 and 70 psi static. Under about 40 psi usually feels weak, especially upstairs. The plumbing code caps static pressure inside the building at 80 psi, and above that a pressure reducing valve is required.
Can I adjust my PRV myself?
Most PRVs have an adjusting screw with a locknut, and turning it clockwise raises pressure. If the valve is old and scaled, though, adjustment often doesn’t hold or the screw is frozen. Make small changes with a gauge on a hose bib, never set it above 80 psi, and if the reading drifts after you adjust it, the valve likely needs replacing.
Why did my pressure drop right after the utility worked on the street?
Main work stirs up sediment and scale, which can get caught in the PRV strainer, the meter screen, faucet aerators or your filter. Clean aerators first. If the whole house is still weak, the strainer ahead of the PRV or a filter cartridge is the next place to look. Also confirm the curb valve was fully reopened.
Do I need an expansion tank?
If your home has a PRV, check valve or backflow preventer on the water service and a tank water heater, the system is closed and the Florida plumbing code requires some means of controlling thermal expansion. An expansion tank at the heater is the usual answer. It also needs its air charge set to match your house pressure.
My well pump clicks on and off constantly. Is it broken?
Usually not yet. Rapid cycling most often means the pressure tank has lost its air precharge or the bladder has failed. Left alone it wears out the pressure switch and the pump motor, so it’s worth having the tank checked soon.
Why is only my hot water pressure low?
That points to something on the hot side: scaled fittings or galvanized nipples at the water heater, a partly closed valve on the heater outlet, a broken dip tube, or sediment in a tankless unit’s inlet screen. Hard water speeds all of these up.
Will a new showerhead fix low pressure?
Only if the old head was clogged. Current showerheads are flow-limited by law, so a new one won’t make a weak system strong. If removing the head entirely doesn’t improve flow much, the problem is in the valve or the supply.
Is high water pressure really a problem if nothing is leaking?
Yes. Pressure over 80 psi wears out fill valves, cartridges, supply hoses and water heater relief valves faster, and it raises the risk of a burst connector. Many homeowners don’t notice until something fails, which is why a gauge test is worth doing.
Why HomeFlow
- One company for service calls, remodels and new construction, so you’re not lining up a different plumber for each job.
- We work in Lee, Charlotte and Collier Counties and know the pipe, water and slab issues that come with homes here.
- Call (239) 518-4198 or send a request online. Tell us what’s going on and where, and we’ll take it from there.
Need a plumber?
Call (239) 518-4198 or send us a request and we’ll get back to you.